METHOD STATEMENT ID: RIGINSP-MS-__________ DATE: ______________ REVISION: ______________
RIG #: ______________ RIG TYPE: ☐ Land ☐ Jackup ☐ Semisub ☐ Drillship
LOCATION: ______________ OPERATOR: ______________ CONTRACTOR: ______________
INSPECTION TYPE: ☐ Pre-spud ☐ Weekly ☐ Monthly ☐ Annual ☐ Critical item
1.0 SCOPE: This procedure covers systematic inspection of all drilling rig equipment and systems.
2.0 RESPONSIBILITIES:
• Toolpusher: Overall inspection coordination • Driller: Floor & rotary equipment
• Chief Mechanic: Engines, pumps, mechanical systems • Chief Electrician: Electrical systems
• Safety Officer: Safety equipment, alarms, PPE • Third-party inspectors (as required)
AREA ITEM STATUS COMMENTS INSPECTOR
RIG FLOOR: Rotary table ☐ OK ☐ Not
Top drive ☐ OK ☐ Not
Iron roughneck ☐ OK ☐ Not
Slips/elevators ☐ OK ☐ Not
Tong dies ☐ OK ☐ Not
Drill line condition ☐ OK ☐ Not
Floor housekeeping ☐ OK ☐ Not
DRAWWORKS: Brake system ☐ OK ☐ Not
Drum/ spooling ☐ OK ☐ Not
Catheads ☐ OK ☐ Not
Guards ☐ OK ☐ Not
Oil levels ☐ OK ☐ Not
MUD PUMPS: Fluid end ☐ OK ☐ Not
Power end ☐ OK ☐ Not
Liners/pistons ☐ OK ☐ Not
Valves ☐ OK ☐ Not
Relief valve ☐ OK ☐ Not
BOP AREA: BOP stack condition ☐ OK ☐ Not
Accumulator pressure ☐ OK ☐ Not
Choke manifold ☐ OK ☐ Not
Kill manifold ☐ OK ☐ Not
Hoses/ lines ☐ OK ☐ Not
ENGINES: Oil levels ☐ OK ☐ Not
Coolant ☐ OK ☐ Not
Belts ☐ OK ☐ Not
Leaks ☐ OK ☐ Not
Exhaust system ☐ OK ☐ Not
SAFETY: Fire extinguishers ☐ OK ☐ Not
SCBA units ☐ OK ☐ Not
Escape packs ☐ OK ☐ Not
H2S monitors ☐ OK ☐ Not
First aid kits ☐ OK ☐ Not
Eye wash stations ☐ OK ☐ Not
Emergency showers ☐ OK ☐ Not
Alarms ☐ OK ☐ Not
ITEM STATUS NEXT DUE INSPECTOR
Drill pipe inspection (visual) ☐ OK ☐ Not _____________ _________
Drill collars inspection ☐ OK ☐ Not _____________ _________
BOP function test ☐ OK ☐ Not _____________ _________
Accumulator pre-charge ☐ OK ☐ Not _____________ _________
Wire rope inspection (crown block) ☐ OK ☐ Not _____________ _________
Wire rope inspection (traveling block) ☐ OK ☐ Not _____________ _________
Wire rope inspection (dead line) ☐ OK ☐ Not _____________ _________
Deadline anchor inspection ☐ OK ☐ Not _____________ _________
Cranes and lifting equipment ☐ OK ☐ Not _____________ _________
Forklifts/ material handlers ☐ OK ☐ Not _____________ _________
Fuel tanks and piping ☐ OK ☐ Not _____________ _________
Mud tank agitators ☐ OK ☐ Not _____________ _________
Shale shakers ☐ OK ☐ Not _____________ _________
Degasser ☐ OK ☐ Not _____________ _________
Desander/ desilter ☐ OK ☐ Not _____________ _________
ITEM STATUS NEXT DUE INSPECTOR
Drill pipe inspection (NDT) ☐ OK ☐ Not _____________ _________
BOP high pressure test ☐ OK ☐ Not _____________ _________
Accumulator pressure test ☐ OK ☐ Not _____________ _________
Derrick/ mast inspection ☐ OK ☐ Not _____________ _________
Substructure inspection ☐ OK ☐ Not _____________ _________
Guy wire tension ☐ OK ☐ Not _____________ _________
Crown-o-matic test ☐ OK ☐ Not _____________ _________
All safety valves tested ☐ OK ☐ Not _____________ _________
Electrical systems inspection ☐ OK ☐ Not _____________ _________
Lighting systems ☐ OK ☐ Not _____________ _________
Generators load test ☐ OK ☐ Not _____________ _________
Fuel and water tanks calibration ☐ OK ☐ Not _____________ _________
Fire detection system test ☐ OK ☐ Not _____________ _________
Gas detection system test ☐ OK ☐ Not _____________ _________
Emergency shutdown system test ☐ OK ☐ Not _____________ _________
ITEM LAST DUE NEXT DUE COMPANY
API derrick/ mast certification ___________ ___________ _________
BOP recertification ___________ ___________ _________
Accumulator certification ___________ ___________ _________
Wire rope replacement ___________ ___________ _________
Crane load test ___________ ___________ _________
Pressure vessels inspection ___________ ___________ _________
Electrical certification ___________ ___________ _________
Fire system certification ___________ ___________ _________
Life raft inspection (offshore) ___________ ___________ _________
Immersion suits inspection (offshore) ___________ ___________ _________
7.1 Drill Line Inspection:
• Inspect for broken wires (max 6 per lay)
• Check for birdcaging, crushing, or kinks
• Measure diameter reduction (max 5%)
• Check lubrication condition
• Record ton-miles and slip/ cut program
7.2 BOP Stack Inspection:
• Visual inspection for damage, corrosion
• Check all bolts/ fasteners torque
• Verify ram type and size for current operation
• Inspect choke and kill lines for erosion
• Check all hydraulic connections
7.3 Traveling Equipment Inspection:
• Inspect traveling block sheaves
• Check hook condition and latch
• Inspect elevator links and ears
• Verify top drive swivel and IBOP function
RIG #: ______________ DATE: ______________ INSPECTION TYPE: ______________
DEFICIENCY REPORT:
# Location Item Deficiency Description Corrective Action Due Date
1 _____________ _____________ ______________ ______________ ________
2 _____________ _____________ ______________ ______________ ________
3 _____________ _____________ ______________ ______________ ________
SUMMARY:
Total items inspected: ______________ Items OK: ______________ Deficiencies: ______________
Critical deficiencies: ______________ Corrected on spot: ______________ Pending: ______________
INSPECTOR: ______________ SIGNATURE: ______________ DATE: ______________
TOOLPUSHER REVIEW: ______________ SIGNATURE: ______________ DATE: ______________
PREPARED BY: ______________ DATE: ______________ APPROVED: ______________ DATE: _____