Free Confined Space Entry Permit (Enhanced) template for oil & gas you can edit online and download as PDF. Covers permit information, entry personnel, hazard identification & risk assessment.
PERMIT NO: CSE-______________ PTW REFERENCE: PTW-______________
PROJECT/FACILITY: ______________ CONTRACTOR: ______________
CONFINED SPACE LOCATION: ______________ SPACE ID/I.D.: ______________
DESCRIPTION OF SPACE: ______________
______________
PURPOSE OF ENTRY: ______________
PERMIT VALIDITY: FROM: ______________ DATE: ______________ TO: ______________ DATE: ______________
(Confined space permits typically valid for ONE SHIFT only - maximum 12 hours)
CLASSIFICATION: Class I (Immediately Dangerous to Life or Health - IDLH) ☐ Class II (Non-IDLH) ☐
Class III (Mechanical Hazard Only) ☐ Alternate Procedures ☐
ENTRY TYPE: Planned Entry ☐ Emergency Rescue ☐ Routine Entry ☐
| ROLE | NAME | COMPANY / ID / CERTIFICATION | ||
|---|---|---|---|---|
| Entry Supervisor (Authorizing) Attendant (Standby Person) Entrant #1 Entrant #2 Entrant #3 Rescue Team Leader Gas Tester | ________ ________ ________ ________ ________ ________ ________ | Cert #: ______________ Cert #: ______________ Training Date: ___________ Training Date: ___________ Training Date: ___________ ________ Cert #: ______________ |
TOTAL NUMBER OF ENTRANTS AUTHORIZED: _____ (Maximum 3 entrants unless special conditions apply)
Check all hazards applicable to this confined space entry:
ATMOSPHERIC HAZARDS: PHYSICAL HAZARDS:
☐ Oxygen Deficiency (<19.5%) ☐ Engulfment hazard (liquids/solids)
☐ Oxygen Enrichment (>23.5%) ☐ Mechanical hazards (moving parts)
☐ Flammable Gas/Vapor (>10% LEL) ☐ Electrical hazards
☐ Hydrogen Sulfide (H2S) ☐ Rotating equipment
☐ Carbon Monoxide (CO) ☐ Thermal hazards (hot/cold surfaces)
☐ Volatile Organic Compounds (VOCs) ☐ Noise >85dB
☐ Toxic gases/vapors (specify) ______________ ☐ Vibration
☐ Inert atmosphere (Nitrogen, etc.) ☐ Radiation
BIOLOGICAL HAZARDS: ERGONOMIC HAZARDS:
☐ Bacteria / Viruses ☐ Restricted entry/exit
☐ Mold / Fungi ☐ Awkward positions
☐ Insects / Pests ☐ Manual handling
☐ Animals / Waste ☐ Slips / trips / falls
OTHER HAZARDS: WORK ACTIVITY HAZARDS:
☐ Cleaning chemicals ☐ Hot work (welding/cutting) - Refer to Hot Work Permit
☐ Residual product ☐ Grinding / cutting
☐ Scale / sludge ☐ Use of chemicals
☐ Previous contents: ______________ ☐ Use of power tools
☐ Unknown hazards ☐ Lighting equipment
ADDITIONAL HAZARD DETAILS: ______________
______________
TEST EQUIPMENT DETAILS:
Gas Detector Model: ______________ Serial #: ______________ Calibration Date: ______________
Calibration Due: ______________ Bump Tested: ☐ Yes ☐ No Time: ______________
ACCEPTANCE CRITERIA:
• Oxygen (O2): 19.5% - 23.5% • Lower Explosive Limit (LEL): < 10%
• Hydrogen Sulfide (H2S): < 10 ppm • Carbon Monoxide (CO): < 25 ppm
• VOC: < _____ ppm • Other (_____): < _____ ppm
INITIAL TEST (Prior to entry):
| TIME | LOCATION | O2 % | LEL % | H2S (ppm) | CO (ppm) | TESTED BY | ||
|---|---|---|---|---|---|---|---|---|
| ______ | ___________ | _______ | _______ | _______ | _______ | ________ |
CONTINUOUS MONITORING:
Continuous monitor in use? ☐ Yes ☐ No Monitor S/N: ______________
Alarm setpoints: O2 <19.5% or >23.5% ☐ LEL >10% ☐ H2S >10 ppm ☐ CO >25 ppm ☐
PERIODIC TESTS (Record all tests during entry):
| TIME | LOCATION | O2 % | LEL % | H2S (ppm) | CO (ppm) | TESTED BY | ||
|---|---|---|---|---|---|---|---|---|
| ______ ______ ______ ______ ______ | ___________ ___________ ___________ ___________ ___________ | _______ _______ _______ _______ _______ | _______ _______ _______ _______ _______ | _______ _______ _______ _______ _______ | _______ _______ _______ _______ _______ | ________ ________ ________ ________ ________ |
ATMOSPHERIC TESTER SIGNATURE: ______________ DATE: ______________
ISOLATION METHODS APPLIED:
MECHANICAL ISOLATION: ELECTRICAL ISOLATION:
☐ Blanking / Blinding (Blind list #: ________) ☐ Breaker locked/tagged (Tag #: ________)
☐ Line break (Location: ______________) ☐ Switch locked/tagged (Tag #: ________)
☐ Valve closed & tagged (Valve #: ________) ☐ Disconnect removed
☐ Double block and bleed ☐ Motor control center (MCC) locked
☐ Spool piece removed ☐ Transformer isolated
☐ Chain/lock on valve ☐ Grounding applied
☐ Physical disconnection ☐ Stored energy dissipated
PROCESS ISOLATION: OTHER ISOLATION:
☐ Purging completed (Medium: ______) ☐ Lines drained/vented
☐ Flushing completed (Medium: ______) ☐ Equipment cleaned
☐ Steam out completed ☐ Cooling lines isolated
☐ Inerting completed (Gas: ______) ☐ Instrumentation isolated
LOTO DETAILS:
LOTO Station #: ______________ Number of Locks Applied: _____ LOTO Verification Date: ______________
LOTO Applied By: ______________ Verified By: ______________
ENERGY SOURCES ISOLATED:
☐ Electrical ☐ Mechanical ☐ Hydraulic ☐ Pneumatic ☐ Chemical ☐ Thermal ☐ Radiation ☐ Gravity
☐ Stored pressure ☐ Spring tension ☐ Other: ______________
ISOLATION VERIFICATION METHOD: ______________
VENTILATION TYPE:
☐ Natural ventilation only ☐ Mechanical ventilation (forced air)
☐ Local exhaust ventilation (LEV) ☐ Combination
MECHANICAL VENTILATION DETAILS:
Fan/Blower ID: ______________ Type: ☐ Air Mover ☐ Blower ☐ Exhaust Fan
CFM Rating: __________ Number of air changes per hour: _____
Air intake location (clean air source): ______________
Ducting: ☐ Supply duct ☐ Exhaust duct ☐ Both Condition: ☐ Good ☐ Damaged
VENTILATION VERIFICATION:
Air flow adequate? ☐ Yes ☐ No Verified by: ______________ Time: ______________
CLEANING METHODS APPLIED:
☐ Water wash ☐ Steam cleaning ☐ Chemical cleaning ☐ Manual cleaning
☐ Abrasive blasting ☐ Vacuum cleaning ☐ Pigging ☐ Other: ______________
RESIDUAL PRODUCTS REMOVED? ☐ Yes ☐ No Product removed: ______________
COMMUNICATION METHODS BETWEEN ATTENDANT AND ENTRANTS:
☐ Voice / Verbal ☐ Two-way radio (Channel: _____) ☐ Hand signals
☐ Rope pull signals ☐ Visual contact ☐ Phone (Number: ______________)
☐ Intercom system ☐ Other: ______________
COMMUNICATION CHECK:
Communication tested and functioning? ☐ Yes ☐ No Time: ______________ Tested by: ______________
Backup communication available? ☐ Yes ☐ No Type: ______________
MONITORING EQUIPMENT:
☐ Personal gas monitors for each entrant
☐ Continuous atmospheric monitor at entry point
☐ Video monitoring (CCTV)
☐ Tripod / Winch / Retrieval system
☐ Full body harness with D-ring for each entrant
☐ Retrieval line attached to each entrant
☐ Mechanical lifting device available
ATTENDANT LOCATION: ______________
ATTENDANT MUST REMAIN AT ENTRY POINT AT ALL TIMES DURING ENTRY OPERATIONS
RESCUE TEAM:
☐ On-site rescue team available and standing by
☐ Off-site rescue team (contact details below)
☐ Rescue equipment at entry point
☐ Rescue drill completed within last 12 months
RESCUE TEAM CONTACT:
Team/Company: ______________ Phone: ______________
Leader Name: ______________ Radio Channel: _____
Estimated response time: ______________ minutes
RESCUE EQUIPMENT AT ENTRY POINT:
☐ Retrieval tripod/winch ☐ Full body harnesses ☐ Retrieval lines
☐ SCBA/SABA (air) ☐ Rescue breathing apparatus ☐ First aid kit
☐ Ladder (adequate length) ☐ Stretcher/litter ☐ Trauma kit
☐ Fire extinguisher ☐ Communication device ☐ Lighting
☐ Other: ______________
EMERGENCY PROCEDURES BRIEFED:
☐ Entrants know evacuation signals
☐ Attendant knows how to initiate rescue
☐ Rescue team aware of location and hazards
☐ Nearest hospital identified and route known
EMERGENCY CONTACTS:
• Emergency Control Room: ______________ Radio: _____ Phone: ______________
• Site Medic/Clinic: ______________ Phone: ______________ Extension: _____
• Nearest Hospital: ______________ Phone: ______________
• Ambulance: ______________ Expected response time: ______________
BRIEFING CONDUCTED BY: ______________ DATE: ______________ TIME: ______________
MANDATORY PPE FOR ENTRY:
☐ Hard hat ☐ Safety glasses ☐ Steel-toed boots ☐ Coveralls (FR if required)
☐ Hearing protection ☐ Gloves (type: ______) ☐ Reflective vest ☐ Other: ______________
ADDITIONAL PPE REQUIRED:
☐ Full body harness ☐ Retrieval line ☐ Wristband/ankle bands ☐ Chemical suit (Type: _____)
☐ SCBA (air) ☐ SAR (air line) ☐ Escape pack (EEBD) ☐ Respirator (Type: _____)
☐ Face shield ☐ Welding helmet ☐ Chemical goggles ☐ Boot covers
☐ Rubber boots ☐ Acid suit ☐ Thermal protection ☐ Other: ______________
ENTRY EQUIPMENT:
☐ Lighting (explosion-proof) ☐ Ladder (non-conductive) ☐ Tools (non-sparking) ☐ Communications equipment
☐ Safety lines ☐ Tripod/winch ☐ First aid kit ☐ Fire extinguisher
☐ Warning signs/barricades ☐ Lockout/tagout devices ☐ Gas detector ☐ Ventilation equipment
PPE VERIFIED BY: ______________ DATE: ______________ TIME: ______________
| ITEM | YES | NO | N/A | INITIALS | COMMENTS |
|---|---|---|---|---|---|
| Confined space identified and classified correctly All hazards identified and assessed Atmospheric testing completed and within limits Continuous monitoring in place (if required) Isolation/LOTO completed and verified Ventilation adequate and operational Space cleaned/purged as required Communication system tested and functioning Rescue equipment available and ready Rescue team on standby/notified Attendant assigned and in position Entrants trained and briefed Entry log book/register in place Warning signs/barricades in place Emergency procedures reviewed All required permits attached (Hot Work, etc.) | ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ | ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ | ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ | ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ | ________ ________ ________ ________ ________ ________ ________ ________ ________ ________ ________ ________ ________ ________ ________ ________ |
PRE-ENTRY CHECKLIST COMPLETED BY (Entry Supervisor): ______________ DATE: ______________
| TIME IN | NAME OF ENTRANT | TIME OUT | DURATION | CONDITIONS OBSERVED | ATTENDANT INITIALS | ||
|---|---|---|---|---|---|---|---|
| ______ ______ ______ ______ ______ ______ ______ | ____________ ____________ ____________ ____________ ____________ ____________ ____________ | ______ ______ ______ ______ ______ ______ ______ | ______ min ______ min ______ min ______ min ______ min ______ min ______ min | ________ ________ ________ ________ ________ ________ ________ | _______ _______ _______ _______ _______ _______ _______ |
ATTENDANT SIGNATURE: ______________ SHIFT: ______________ DATE: ______________
RELIEVED ATTENDANT SIGNATURE: ______________ TIME: ______________ DATE: ______________
PERMIT APPLICANT / ENTRY SUPERVISOR (Confirms space prepared, hazards assessed, controls in place):
I certify that this confined space has been properly prepared, all hazards assessed, and all
required controls are in place for safe entry.
Signature: ______________ Date: ______________ Time: ______________
ATTENDANT (Confirms understanding of duties and emergency procedures):
I understand my duties as Attendant and will remain at the entry point for the duration of the entry.
Signature: ______________ Date: ______________ Time: ______________
ENTRANTS (Confirms understanding of hazards, procedures, and emergency signals):
I have been briefed on the hazards, understand the emergency procedures, and consent to enter.
Signature: ______________ Date: ______________ Time: ______________
Signature: ______________ Date: ______________ Time: ______________
Signature: ______________ Date: ______________ Time: ______________
OPERATIONS / AREA AUTHORITY (Confirms area release for entry):
Signature: ______________ Date: ______________ Time: ______________
SAFETY REPRESENTATIVE (If required):
Signature: ______________ Date: ______________ Time: ______________
FINAL APPROVAL - PERMIT ISSUED BY (Authorized Gas Tester / HSE / Site Manager):
Signature: ______________ Date: ______________ Time: ______________
PERMIT VALID FOR ENTRY BETWEEN: Start: ______________ Date: ______________ End: ______________ Date: ___________
ENTRY COMPLETED / SUSPENDED / TERMINATED:
Date: ______________ Time: ______________
☐ Entry completed as planned
☐ Entry suspended (reason): ______________
☐ Entry terminated due to emergency/unsafe condition: ______________
ENTRANTS ACCOUNTED FOR:
Total entrants at start: _____ Total entrants accounted for at end: _____
Are all entrants out of confined space? ☐ Yes ☐ No (If No, explain: ______________)
EQUIPMENT SHUTDOWN/REMOVAL:
☐ Ventilation equipment turned off and removed
☐ Monitoring equipment removed
☐ Lighting equipment removed
☐ Barriers/warning signs removed (if appropriate)
☐ Tools and equipment removed
SPACE SECURED:
☐ Entry point secured/covered
☐ Locks/tags removed (if applicable)
☐ Isolation removed (if applicable)
☐ Space returned to Operations
ATTENDANT DECLARATION:
I confirm that all entrants have exited the confined space, the space has been secured,
and the area is left in a safe condition.
Signature: ______________ Date: ______________ Time: ______________
ENTRY SUPERVISOR DECLARATION:
I confirm that the confined space entry has been completed/suspended and all personnel are
accounted for. The space has been made safe and returned to service/secured.
Signature: ______________ Date: ______________ Time: ______________
OPERATIONS / AREA AUTHORITY (Space handover acceptance):
Signature: ______________ Date: ______________ Time: ______________
EXTENSION #1:
New Expiry Date: ______________ Time: ______________ Reason: ______________
Atmospheric testing re-verified: ☐ Yes ☐ No Test results acceptable: ☐ Yes ☐ No
Authorized by: ______________ Signature: ______________ Date: ________
EXTENSION #2:
New Expiry Date: ______________ Time: ______________ Reason: ______________
Atmospheric testing re-verified: ☐ Yes ☐ No Test results acceptable: ☐ Yes ☐ No
Authorized by: ______________ Signature: ______________ Date: ________
Any incidents, near misses, or unsafe conditions during this confined space entry:
☐ No incidents/near misses
☐ Incident occurred (complete below)
☐ Near miss occurred (complete below)
☐ Unsafe condition observed (complete below)
DESCRIPTION: ______________
______________
______________
REPORTED BY: ______________ Date: ______________ Time: ______________
REPORT NUMBER (if applicable): ______________
THIS PERMIT IS VALID ONLY FOR THE DATE AND TIME SPECIFIED - ONE ENTRY PER SHIFT
ALL CONDITIONS MUST BE RE-VERIFIED IF WORK IS NOT COMPLETED