Free Hot Work Operations Risk Assessment template for oil & gas you can edit online and download as PDF. Covers hot work information, hot work risk assessment matrix, hot work area inspection checklist.
ASSESSMENT ID: HOT-__________ DATE: ______________ TIME: ______________
FACILITY NAME: ______________ LOCATION: ______________ UNIT/AREA: ______________
WORK DESCRIPTION: ______________
WORK TYPE: Welding ☐ Grinding ☐ Cutting ☐ Brazing ☐ Soldering ☐ Hot tapping ☐ Other: ______________
EQUIPMENT TO BE USED: ______________
PERMIT NUMBER: ______________ PTW REFERENCE: ______________
| HAZARD CATEGORY | HAZARD DESCRIPTION | POTENTIAL CONSEQUENCE | EXISTING CONTROLS | LIKELIHOOD (1-5) | SEVERITY (A-E) | RISK INDEX |
|---|---|---|---|---|---|---|
| Fire | -Ignition of combustibles in area -Ignition of hydrocarbons -Sparks entering openings -Undetected smoldering | -Personnel burns -Property damage -Fatality -Facility shutdown | -Area inspection -Fire extinguishers -Fire watch -Cover combustibles -Wet down -Fire blankets | 4 (Probable) | E (Catastrophic) | 16 (EXTREME) |
| Explosion | -Ignition of flammable gas/vapor -Welding on containers with residue -Confined space explosion | -Multiple fatalities -Total loss of facility -Environmental release | -Gas testing -Continuous monitoring -Isolation of flammables -Purging -Ventilation -Hot work permit | 3 (Occasional) | E (Catastrophic) | 12 (HIGH) |
| Health Hazards | -Fumes/gases from welding (ozone, NOx, CO) -Coated materials (galvanized, painted) -Cadmium/ chromium -Inert gas (argon) | -Respiratory illness -Metal fume fever -Poisoning -Long-term health effects | -Local exhaust ventilation -Respirator (type: ______) -LEV -Work position -Air monitoring | 4 (Probable) | D (Hazardous) | 12 (HIGH) |
| Physical Hazards | -Burns from hot work (metal, slag) -UV radiation (arc flash) -Electrical shock -Compressed gas cylinders (O2, fuel) -Hot slag | -Skin burns -Eye injury -Arc eye (welding flash) -Electric shock -Fire from cylinder rupture | -PPE (leather apron, gloves) -Welding helmet -Leathers -Insulated holder -Cylinder storage | 5 (Almost Certain) | C (Major) | 10 (HIGH) |
| SIMOPS Hazards | -Hot work near production operations -Hot work near other crews -Conflicting activities -Adjacent hot work areas | -Ignition of release -Fire/ explosion -Injury to others -Escalation | -SIMOPS permit -Gas testing -Continuous monitoring -Barricading -Fire watch -Shutdown plan | 4 (Probable) | D (Hazardous) | 12 (HIGH) |
AREA PREPARATION (To be completed before hot work begins)
| ☐ Area inspected for fire hazards - By: ______________ Date: ______________ ☐ Flammable/combustible materials removed within 35 ft (11 m) ☐ Combustible floors wet down or covered with fire blankets/sand ☐ Wall/floor openings covered or protected to prevent sparks from entering ☐ Fire-resistant covers/blankets in place to protect equipment ☐ All flammable liquid/gas lines in area isolated and blanked ☐ Adjacent areas checked for combustible materials/atmospheres ☐ Sewers, pits, trenches in area covered or sealed ☐ Fire extinguishers in place and accessible - Type: ______________ #: ______ ☐ Fire hoses connected and ready - Hose #: ______________ Pressure: ______ psi ☐ Fire alarm pull station accessible - Location: ______________ ☐ Emergency exits clear and accessible ☐ "HOT WORK IN PROGRESS" signs posted ☐ Barricades/warning tape in place around work area |
|---|
GAS TESTING:
| TEST TIME | LOCATION | O2 % | LEL % | TOXIC (ppm) | TESTER | COMMENTS | |
|---|---|---|---|---|---|---|---|
| ___________ ___________ ___________ ___________ ___________ | Work area 10 ft radius Adjacent area Below work area Pits/trenches | _______ _______ _______ _______ _______ | ________ ________ ________ ________ ________ | ___________ ___________ ___________ ___________ ___________ | ___________ ___________ ___________ ___________ ___________ | ________ ________ ________ ________ ________ |
ACCEPTABLE RANGES: O2: 19.5-23.5% LEL: <10% (Hydrocarbon area) / <5% (Special area)
☐ Continuous gas monitoring required - Monitor ID: ______________ Location: ______________
☐ Frequent re-testing required - Frequency: ______________
WELDING/CUTTING EQUIPMENT:
| EQUIPMENT ________ Welding machine Welding leads/cables Electrode holder Ground clamp Welding helmet/lens Torch (cutting/welding) Flash arrestors Hose condition Hose connections/fittings Cylinder carts Cylinder caps Cylinder storage | INSPECTED _________ Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No | CONDITION __________ Good/Damage Good/Damage Good/Damage Good/Damage Good/Damage Good/Damage Present Good/Damage Tight Good/Damage| Secured properly Present Upright/secured | COMMENTS ________ ________ ________ ________ ________ Shade #: _____ ________ On both O2 and fuel No leaks/cuts Clamps/ferrules in place In place when not in use O2 & fuel separated ≥20 ft |
|---|
FIRE EXTINGUISHERS:
| TYPE _________ ABC (10#) CO2 Water Hose reel | LOCATION ________ At work area At work area Nearby 50 ft from area | LAST INSPECT ____________ ____________ ____________ ____________ ____________ | PRESSURE ________ Good/Low Good/Low Good/Low Good/Low | STATUS _________ Ready Ready Ready Ready | SUITABLE FOR WORK? ________ Yes ☐ No ☐ Yes ☐ No ☐ Yes ☐ No ☐ Yes ☐ No ☐ |
|---|
PERMIT NUMBER: HOT-_____________ DATE: ______________ EXPIRY: ______________
WORKER INFORMATION:
Welder/Operator: ______________ Company: ______________ Cert #: ______________
Fire Watch: ______________ Company: ______________ Trained: Yes ☐ No ☐
Supervisor: ______________ Company: ______________
DURATION:
Start Date: ______________ Start Time: ______________ End Date: ______________ End Time: ______________
(Hot work permits typically valid for one shift only - maximum 12 hours)
SPECIAL CONDITIONS:
______________
______________
FIRE WATCH REQUIREMENTS:
☐ Fire watch required during work
☐ Fire watch required for 30/60 minutes after work (for smoldering fires)
☐ Fire watch location: At work area ☐ Adjacent areas ☐ Below work ☐ Both ☐
☐ Fire watch equipment: Radio ☐ Extinguisher ☐ Hose ☐ Fire blanket ☐
AUTHORIZATIONS:
Area Authority: ______________ Signature: ______________ Time: ______________
PTW Coordinator: ______________ Signature: ______________ Time: ______________
HSE/Safety: ______________ Signature: ______________ Time: ______________
I HAVE READ AND UNDERSTAND THIS PERMIT:
Welder: ______________ Signature: ______________ Time: ______________
Fire Watch: ______________ Signature: ______________ Time: ______________
FIRE WATCH RESPONSIBILITIES:
☐ Maintain continuous watch during hot work
☐ Watch for fires in all exposed areas
☐ Have fire extinguishing equipment ready
☐ Know how to activate fire alarm
☐ Know how to call for help
☐ Watch for changing conditions
☐ Stop work if unsafe conditions develop
☐ Maintain communication with welder
☐ Remain in area until relieved
☐ Perform post-work fire watch (30-60 min)
FIRE WATCH LOG:
| TIME | CONDITIONS | OBSERVATIONS | FIRE WATCH INITIALS | ||
|---|---|---|---|---|---|
| ___________ ___________ ___________ ___________ ___________ ___________ | Normal/Alert Normal/Alert Normal/Alert Normal/Alert Normal/Alert Normal/Alert | ________ ________ ________ ________ ________ ________ | ________ ________ ________ ________ ________ ________ |
IS WORK ON OR NEAR:
☐ Piping/vessels that HAVE contained flammables?
☐ Piping/vessels that HAVE contained toxics?
☐ Piping/vessels currently in service?
☐ Electrical equipment?
☐ Coated/painted surfaces?
IF YES TO ANY ABOVE, COMPLETE THIS SECTION:
| CONTAINER/PIPE PREPARATION: ☐ Isolated (blinded/ disconnected) - Method: ______________ Verified by: ______________ ☐ Drained and depressurized - Pressure: 0 psi ☐ Verified by: ______________ ☐ Purged - Method: ______________ Duration: ______________ Verified by: ______________ ☐ Cleaned - Method: ______________ Verified by: ______________ ☐ Ventilated - Method: ______________ Verified by: ______________ ☐ Tested for flammables - Result: <10% LEL ☐ Tested by: ______________ ☐ Tested for toxics - Result: Acceptable ☐ Tested by: ______________ ☐ Grounded/bonded - Method: ______________ Verified by: ______________ | |
|---|---|
| SPECIAL TECHNIQUES: ☐ Hot tap procedure required - Procedure #: ______________ ☐ Positive pressure maintained - Medium: ______________ Pressure: ______ psi ☐ Inert atmosphere maintained - Gas: ______________ Monitoring: ______________ ☐ Continuous gas monitoring required - Monitor ID: ______________ ☐ Additional fire protection - Type: ______________ Location: ______________ |
MINIMUM PPE FOR HOT WORK:
| ☐ Flame Resistant (FR) Clothing - Material: ______________ Condition: Good ☐ Damaged ☐ ☐ Welding Leathers - Jacket ☐ Apron ☐ Sleeves ☐ Condition: Good ☐ Damaged ☐ ☐ Welding Gloves - Type: ______________ Condition: Good ☐ Damaged ☐ ☐ Welding Helmet - Shade #: ______ Auto-darkening ☐ Fixed shade ☐ Condition: Good ☐ Damaged ☐ ☐ Safety Glasses (under helmet) - Condition: Good ☐ Damaged ☐ ☐ Hearing Protection - Type: ______________ Condition: Good ☐ Damaged ☐ ☐ Steel Toe Boots - Condition: Good ☐ Damaged ☐ ☐ Respiratory Protection - Type: ______________ Cartridge: ______________ ☐ Head Protection - Hard hat ☐ Welding cap ☐ ☐ Leather spats/gaiter - Required for overhead work? Yes ☐ No ☐ |
|---|
PPE VERIFICATION:
I confirm that all personnel involved have the required PPE and it is in good condition:
Supervisor: ______________ Signature: ______________ Date: ______________
WORK COMPLETION:
| ☐ Work completed at: ______________ Date: ______________ ☐ Equipment shut down and secured ☐ Cylinder valves closed and caps on ☐ Work area cleaned of debris/slag ☐ All combustible materials removed ☐ Fire extinguishers returned to normal location ☐ Barricades/signs removed |
|---|
POST-WORK FIRE WATCH:
| FIRE WATCH REQUIRED AFTER WORK COMPLETION: ☐ 30-minute fire watch (for normal hot work) ☐ 60-minute fire watch (for high-risk work, near combustibles) ☐ Extended fire watch required - Duration: ______________ Reason: ______________ | |
|---|---|
| POST-WORK FIRE WATCH LOG: |
| TIME | AREA CHECKED | OBSERVATIONS | FIRE WATCH INITIALS | |||
|---|---|---|---|---|---|---|
| ___________ ___________ ___________ ___________ ___________ | Work area Below work Adjacent Work area All areas | ________ ________ ________ ________ ________ | ________ ________ ________ ________ ________ |
FINAL INSPECTION:
| I have inspected the work area and confirmed no signs of fire or smoldering. Fire Watch: ______________ Signature: ______________ Time: ______________ Supervisor: ______________ Signature: ______________ Time: ______________ |
|---|
PERMIT CLOSURE CHECKLIST:
| ☐ Work completed per permit ☐ Post-work fire watch completed ☐ Area inspected and found safe ☐ Equipment removed/stored properly ☐ Gas cylinders removed or secured ☐ Fire extinguishers in place ☐ Barricades removed ☐ Signs removed ☐ Area returned to normal condition ☐ Permit returned to PTW office |
|---|
CLOSURE SIGNATURES:
Supervisor: ______________ Signature: ______________ Time: ______________
PTW Coordinator: ______________ Signature: ______________ Time: ______________
PERMIT CLOSED AT: ______________ DATE: ______________
IN CASE OF FIRE:
1. STOP WORK IMMEDIATELY
2. Sound the alarm - Pull station location: ______________
3. Attempt to extinguish if small - Use appropriate extinguisher
4. EVACUATE if fire cannot be controlled
5. Account for personnel at muster point: ______________
6. Notify emergency response: ______________ Phone: ______________
IN CASE OF GAS RELEASE / ALARM:
1. STOP WORK IMMEDIATELY
2. Shut off all ignition sources
3. Evacuate area
4. Follow facility emergency procedures
IN CASE OF INJURY:
1. STOP WORK
2. Provide first aid
3. Call for medical assistance: ______________ Phone: ______________
4. Notify supervisor
| # | ACTION REQUIRED | RESPONSIBLE | DUE DATE | STATUS | ||
|---|---|---|---|---|---|---|
| 1 2 3 4 | Replace worn welding leads (insulation cracked) Calibrate gas monitor #HW-03 Replenish fire blanket at welding station ________ | _____________ _____________ _____________ _____________ | _____________ _____________ _____________ _____________ | Open ☐ In Prog ☐ Complete ☐ Open ☐ In Prog ☐ Complete ☐ Open ☐ In Prog ☐ Complete ☐ Open ☐ In Prog ☐ Complete ☐ |
ASSESSMENT TEAM:
Name: ______________ Title: Welding Supervisor Signature: ______________
Name: ______________ Title: Safety Officer Signature: ______________
Name: ______________ Title: Fire Watch Signature: ______________
Name: ______________ Title: Area Authority Signature: ______________
APPROVALS:
Operations Manager: ______________ Date: ______________ Signature: ______________
HSE Manager: ______________ Date: ______________ Signature: ______________
PTW Coordinator: ______________ Date: ______________ Signature: ______________
REVIEW DATE: ______________ NEXT REVIEW DATE: ______________