Free H2S Entry Permit (Enhanced) template for oil & gas you can edit online and download as PDF. Covers permit information, entry team & qualifications, h2s hazard awareness & properties.
PERMIT NO: H2S-______________ PTW REFERENCE: PTW-______________
PROJECT/FACILITY: ______________ CONTRACTOR: ______________
WORK LOCATION: ______________ AREA/UNIT: ______________
EQUIPMENT/SPACE DESCRIPTION: ______________
______________
WORK DESCRIPTION: ______________
______________
PERMIT VALIDITY: FROM: ______________ DATE: ______________ TO: ______________ DATE: ______________
(H2S Entry permits typically valid for ONE SHIFT only - maximum 12 hours)
H2S CLASSIFICATION: ☐ Classified H2S Area ☐ Potential H2S Present ☐ Confirmed H2S Present
☐ Emergency Response ☐ Routine Entry
H2S CONCENTRATION EXPECTED: ☐ <10 ppm ☐ 10-100 ppm ☐ 100-1000 ppm ☐ >1000 ppm (IDLH)
| ROLE | NAME | H2S CERTIFICATION / TRAINING | ||
|---|---|---|---|---|
| Entry Supervisor Attendant / Standby Person Entrant #1 Entrant #2 Entrant #3 Rescue Team Leader Gas Tester Safety Representative | ________ ________ ________ ________ ________ ________ ________ ________ | Cert #: ______________ Exp: _______ Cert #: ______________ Exp: _______ Cert #: ______________ Exp: _______ Cert #: ______________ Exp: _______ Cert #: ______________ Exp: _______ Cert #: ______________ Exp: _______ Cert #: ______________ Exp: _______ ________ |
TOTAL NUMBER OF ENTRANTS AUTHORIZED: _____ (Maximum entrants based on rescue capability)
H2S TRAINING VERIFICATION:
All personnel have current H2S training? ☐ Yes ☐ No
All personnel have current escape breathing apparatus training? ☐ Yes ☐ No
All personnel have current SCBA training? ☐ Yes ☐ No (if applicable)
All personnel fit-tested for respiratory protection? ☐ Yes ☐ No
HYDROGEN SULFIDE (H2S) PROPERTIES:
• Color: Colorless gas • Odor: Rotten eggs (at low concentrations)
• Odor threshold: 0.0005 - 0.1 ppm • Olfactory fatigue: Occurs rapidly (>100 ppm)
• Specific Gravity: 1.19 (heavier than air) • Flammable range: 4.3% - 46% in air
• IDLH (Immediately Dangerous to Life and Health): 100 ppm
• PEL (Permissible Exposure Limit - OSHA): 10 ppm (8-hour TWA)
• STEL (Short Term Exposure Limit - 15 min): 15 ppm
H2S EXPOSURE EFFECTS:
| CONCENTRATION | EFFECTS | ||
|---|---|---|---|
| 0.01 - 1.5 ppm 2 - 5 ppm 10 - 20 ppm 20 - 100 ppm 100 - 200 ppm 200 - 300 ppm 300 - 500 ppm 500 - 1000 ppm >1000 ppm | Odor threshold (rotten eggs) Moderate odor, possible headache, nausea Eye irritation, permissible exposure limit Fatigue, loss of appetite, headache, irritability, poor memory, dizziness Severe eye and respiratory irritation, olfactory fatigue (cannot smell) Severe inflammation of eyes/throat, pulmonary edema, loss of consciousness Pulmonary edema, unconsciousness, respiratory paralysis, death Rapid unconsciousness, respiratory arrest, death within minutes Immediate respiratory paralysis, coma, death within seconds |
Check all hazards applicable to this H2S entry:
H2S-RELATED HAZARDS:
☐ H2S present (known) ☐ Oxygen deficiency (<19.5%)
☐ H2S potential (unknown concentration) ☐ Oxygen enrichment (>23.5%)
☐ H2S >10 ppm (action level) ☐ Flammable gas/vapor (>10% LEL)
☐ H2S >100 ppm (IDLH) ☐ Carbon Monoxide (CO)
☐ H2S >1000 ppm (immediate fatality risk) ☐ Sulfur Dioxide (SO2)
☐ H2S accumulation in low-lying areas ☐ Volatile Organic Compounds (VOCs)
☐ H2S in confined spaces ☐ Other toxic gases: ______________
☐ H2S in excavations / pits ☐ ______________
☐ H2S in process equipment/vessels ☐ ______________
PHYSICAL HAZARDS:
☐ Confined space entry ☐ Hot work (welding/cutting)
☐ Engulfment hazard ☐ Grinding / cutting
☐ Fire / Explosion (H2S is flammable) ☐ Use of chemicals
☐ Electrical hazards ☐ Use of power tools
☐ Mechanical hazards ☐ Lighting equipment
☐ Noise >85dB ☐ Manual handling
☐ Slips / trips / falls ☐ Working at height
☐ Limited access/egress ☐ Other: ______________
ADDITIONAL HAZARD DETAILS: ______________
______________
TEST EQUIPMENT DETAILS:
Gas Detector Model: ______________ Serial #: ______________ Calibration Date: ______________
H2S Sensor Range: ______________ ppm Last Bump Test: ______________ Results: ☐ Pass ☐ Fail
Calibration Due: ______________ Bump Tested Today: ☐ Yes ☐ No Time: ______________
ACCEPTANCE CRITERIA FOR ENTRY:
• Oxygen (O2): 19.5% - 23.5%
• Hydrogen Sulfide (H2S): < 10 ppm (Action Level) - **MUST BE <10ppm FOR ENTRY**
• Lower Explosive Limit (LEL): < 10%
• Carbon Monoxide (CO): < 25 ppm
• Sulfur Dioxide (SO2): < 2 ppm (if applicable)
• Other gases: ______________ < _____ ppm
INITIAL TEST (Prior to entry):
| TIME | LOCATION | O2 % | H2S (ppm) | LEL % | CO (ppm) | TESTED BY | ||
|---|---|---|---|---|---|---|---|---|
| ______ | ___________ | _______ | _______ | _______ | _______ | ________ |
CONTINUOUS MONITORING REQUIREMENTS:
Continuous monitor required? ☐ Yes ☐ No Monitor S/N: ______________
Personal H2S monitors required for each entrant? ☐ Yes ☐ No
Alarm setpoints:
• H2S: ☐ 10 ppm (Warning) ☐ 15 ppm (STEL) ☐ 100 ppm (IDLH - Immediate evacuation)
• O2: <19.5% or >23.5%
• LEL: >10%
PERIODIC TESTS (Record all tests during entry):
| TIME | LOCATION | O2 % | H2S (ppm) | LEL % | CO (ppm) | TESTED BY | ||
|---|---|---|---|---|---|---|---|---|
| ______ ______ ______ ______ ______ | ___________ ___________ ___________ ___________ ___________ | _______ _______ _______ _______ _______ | _______ _______ _______ _______ _______ | _______ _______ _______ _______ _______ | _______ _______ _______ _______ _______ | ________ ________ ________ ________ ________ |
ACTION LEVELS & RESPONSE:
• If H2S ≥ 10 ppm: STOP WORK, EVACUATE immediately, investigate source
• If H2S ≥ 100 ppm: EMERGENCY - IDLH - Evacuate, initiate rescue if personnel affected
• If O2 < 19.5%: STOP WORK, EVACUATE immediately
• If LEL > 10%: STOP WORK, EVACUATE immediately, eliminate ignition sources
ATMOSPHERIC TESTER SIGNATURE: ______________ DATE: ______________
RESPIRATORY PROTECTION SELECTION (Based on H2S Concentration):
| CONCENTRATION | REQUIRED RESPIRATORY PROTECTION | ||
|---|---|---|---|
| < 10 ppm 10 - 100 ppm > 100 ppm (IDLH) Unknown / Potential | No respirator required (monitoring only) Full face respirator with H2S cartridges OR PAPR with H2S cartridges SCBA (Self-Contained Breathing Apparatus) OR SAR with escape bottle SCBA or SAR with escape bottle (treat as IDLH until proven otherwise) |
RESPIRATORY EQUIPMENT SELECTED:
☐ No respirator required (H2S <10 ppm, continuous monitoring)
☐ Half-face respirator with H2S cartridges (Not for IDLH)
☐ Full-face respirator with H2S cartridges (Not for IDLH)
☐ PAPR (Powered Air Purifying Respirator) with H2S cartridges
☐ SCBA (Self-Contained Breathing Apparatus)
☐ SAR (Supplied Air Respirator) with escape bottle
☐ Combination: SAR with SCBA backup
SCBA / SAR DETAILS:
Equipment ID: ______________ Last Inspection: ______________
Cylinder Pressure: ______________ psi (Minimum 90% full)
Duration of air supply: ______________ minutes
Low pressure alarm working? ☐ Yes ☐ No
Face piece fit test current? ☐ Yes ☐ No Fit test date: ______________
RESPIRATORY EQUIPMENT INSPECTED BY: ______________ DATE: ______________
PERSONAL H2S MONITORS:
| ASSIGNED TO | MONITOR ID | BUMP TESTED | ALARM TEST | INITIAL READING | ||
|---|---|---|---|---|---|---|
| ________ ________ ________ ________ ________ | ____________ ____________ ____________ ____________ ____________ | ☐ Yes ☐ No ☐ Yes ☐ No ☐ Yes ☐ No ☐ Yes ☐ No ☐ Yes ☐ No | ☐ Yes ☐ No ☐ Yes ☐ No ☐ Yes ☐ No ☐ Yes ☐ No ☐ Yes ☐ No | ________ ppm ________ ppm ________ ppm ________ ppm ________ ppm |
AREA / CONTINUOUS MONITORS:
| LOCATION | MONITOR ID | BUMP TESTED | ALARM TEST | INITIAL READING | ||
|---|---|---|---|---|---|---|
| ________ ________ | ____________ ____________ | ☐ Yes ☐ No ☐ Yes ☐ No | ☐ Yes ☐ No ☐ Yes ☐ No | ________ ppm ________ ppm |
ALARM RESPONSE PROCEDURES BRIEFED:
☐ Single alarm (H2S >10 ppm) - Stop work, evaluate, evacuate if sustained
☐ Double alarm (H2S >15 ppm or STEL) - Immediate evacuation
☐ Continuous alarm (H2S >100 ppm IDLH) - Emergency evacuation, rescue if needed
☐ Low battery alarm - Exit area immediately
☐ Fault alarm - Exit area immediately
MONITORING EQUIPMENT VERIFIED BY: ______________ DATE: ______________
VENTILATION REQUIRED? ☐ Yes ☐ No
VENTILATION TYPE:
☐ Natural ventilation only
☐ Mechanical ventilation (forced air)
☐ Local exhaust ventilation
☐ Dilution ventilation
MECHANICAL VENTILATION DETAILS:
Fan/Blower ID: ______________ Type: ☐ Air Mover ☐ Blower ☐ Exhaust Fan
CFM Rating: __________ Location: ______________
Air intake from clean source? ☐ Yes ☐ No Source: ______________
Ducting: ☐ Supply duct ☐ Exhaust duct ☐ Both Condition: ☐ Good ☐ Damaged
VENTILATION VERIFICATION:
Air flow adequate? ☐ Yes ☐ No Verified by: ______________ Time: ______________
H2S levels with ventilation: ______________ ppm
ISOLATION METHODS APPLIED:
☐ Process isolation (blinds/blank) - Blind list #: ______________
☐ Valve closed and tagged - Valve #: ______________
☐ Line break - Location: ______________
☐ Electrical isolation - LOTO applied
☐ Equipment drained and flushed
☐ Equipment purged - Medium: ______________
☐ Equipment ventilated
☐ Positive isolation verified
LOTO DETAILS:
LOTO Station #: ______________ Number of Locks Applied: _____ LOTO Verification Date: ______________
LOTO Applied By: ______________ Verified By: ______________
ISOLATION VERIFICATION METHOD: ______________
RESCUE TEAM:
☐ On-site H2S rescue team available and standing by
☐ Off-site rescue team (contact details below)
☐ Rescue team equipped with SCBA
☐ Rescue team trained in H2S rescue
RESCUE TEAM CONTACT:
Team/Company: ______________ Phone: ______________
Leader Name: ______________ Radio Channel: _____
Estimated response time: ______________ minutes
RESCUE EQUIPMENT AT ENTRY POINT:
☐ SCBA sets (Number: _____) ☐ Spare air cylinders (Number: _____)
☐ SAR with escape bottles ☐ Rescue harness / lines
☐ Retrieval tripod/winch ☐ Stretcher / litter
☐ First aid kit / Oxygen ☐ AED / CPR equipment
☐ Communication equipment ☐ H2S antidote (Amyl Nitrite) if available
☐ Other: ______________
EMERGENCY PROCEDURES:
IF H2S ALARM ACTIVATES:
1. ALL PERSONNEL - EVACUATE IMMEDIATELY to upwind assembly area
2. Attendant - Account for all entrants, do not enter to rescue
3. Entry Supervisor - Initiate emergency response, contact rescue team
4. Rescue Team - Don SCBA, perform rescue if safe to do so
5. Do NOT enter without SCBA - H2S is immediately fatal
IF PERSONNEL COLLAPSE / UNCONSCIOUS:
1. DO NOT ENTER WITHOUT SCBA - Rescuers become victims
2. Rescue Team with SCBA to retrieve victim
3. Move victim to fresh air immediately
4. Administer CPR if trained and equipped
5. Administer oxygen if available and trained
6. Seek immediate medical attention
EMERGENCY CONTACTS:
• Emergency Control Room: ______________ Radio: _____ Phone: ______________
• H2S Rescue Team: ______________ Radio: _____ Phone: ______________
• Site Medic/Clinic: ______________ Phone: ______________ Extension: _____
• Nearest Hospital: ______________ Phone: ______________
• Poison Control: ______________ Phone: ______________
EMERGENCY ASSEMBLY POINT (UPWIND): ______________
RESCUE PROCEDURES BRIEFED TO ALL PERSONNEL? ☐ Yes ☐ No
RESCUE DRILL COMPLETED WITHIN LAST 12 MONTHS? ☐ Yes ☐ No
BRIEFING CONDUCTED BY: ______________ DATE: ______________ TIME: ______________
MANDATORY PPE:
☐ Hard hat ☐ Safety glasses ☐ Steel-toed boots ☐ Coveralls (FR if required)
☐ Hearing protection ☐ Gloves (chemical resistant)
H2S-SPECIFIC PPE:
☐ Personal H2S monitor ☐ SCBA / SAR (as required) ☐ Escape pack (EEBD) ☐ Respirator (Type: _____)
☐ Goggles (gas-tight) ☐ Face shield ☐ Chemical suit ☐ Rubber boots
ADDITIONAL EQUIPMENT:
☐ Windsock / Wind direction indicator ☐ Communication radios
☐ Warning signs / Placards ("DANGER - H2S AREA") ☐ Barricades / Safety tape
☐ First aid kit / Oxygen ☐ Eye wash station
☐ Fire extinguisher ☐ Lighting (explosion-proof)
☐ Decontamination equipment ☐ Other: ______________
WINDSOCK LOCATION: ______________ Wind direction visible from work area? ☐ Yes ☐ No
PPE VERIFIED BY: ______________ DATE: ______________ TIME: ______________
H2S AREA CLASSIFICATION:
☐ Zone 0 - H2S present continuously or for long periods
☐ Zone 1 - H2S likely to occur in normal operations
☐ Zone 2 - H2S not likely in normal operations, but could occur
☐ Unclassified - No H2S expected
H2S HAZARD ZONES ESTABLISHED:
Hot Zone (IDLH / >100 ppm): ______________
Warm Zone (Decontamination): ______________
Cold Zone (Safe / Support): ______________
ACCESS CONTROL:
☐ Access restricted to authorized personnel only
☐ Entry log maintained
☐ Buddy system required
☐ Continuous monitoring required
| ITEM | YES | NO | N/A | INITIALS | COMMENTS |
|---|---|---|---|---|---|
| H2S hazards identified and assessed Atmospheric testing completed - H2S <10 ppm Continuous monitoring in place Personal H2S monitors assigned and tested Respiratory protection selected and available SCBA/SAR inspected and pressure checked (if required) Escape packs / EEBD available (if required) Isolation/LOTO completed and verified Ventilation adequate and operational Rescue equipment available and ready Rescue team on standby/notified Emergency procedures reviewed with all team Attendant assigned and in position Entrants trained and briefed Communications tested and functioning Windsock / wind direction visible Warning signs / barricades in place All required permits attached (Confined Space, Hot Work) Toolbox talk / pre-entry meeting completed | ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ | ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ | ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ | ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ | ________ Reading: _____ ppm ________ ________ Type: _________ Pressure: _____ psi ________ ________ ________ ________ ________ ________ ________ ________ Channel: _____ Direction: _____ ________ Permit #: _________ ________ |
PRE-ENTRY CHECKLIST COMPLETED BY (Entry Supervisor): ______________ DATE: ______________
TOPICS COVERED:
☐ H2S properties & effects ☐ H2S concentrations & action levels
☐ Monitoring equipment & alarms ☐ Alarm response procedures
☐ Respiratory protection - selection & use ☐ SCBA / SAR - donning & operation
☐ Escape procedures ☐ Emergency assembly point (upwind)
☐ Rescue procedures ☐ Do NOT enter to rescue without SCBA
☐ Communication methods ☐ Stop work authority
☐ First aid / CPR / Oxygen administration ☐ Emergency contacts
ATTENDEES:
| NAME | ROLE | COMPANY | SIGNATURE | ||
|---|---|---|---|---|---|
| ________ ________ ________ ________ ________ ________ ________ | ________ ________ ________ ________ ________ ________ ________ | ________ ________ ________ ________ ________ ________ ________ | ________ ________ ________ ________ ________ ________ ________ |
MEETING CONDUCTED BY: ______________ DATE: ______________ TIME: ______________
| TIME IN | NAME OF ENTRANT | TIME OUT | DURATION | H2S MONITOR READINGS | ATTENDANT INITIALS | ||
|---|---|---|---|---|---|---|---|
| ______ ______ ______ ______ ______ ______ | ____________ ____________ ____________ ____________ ____________ ____________ | ______ ______ ______ ______ ______ ______ | ______ min ______ min ______ min ______ min ______ min ______ min | Max: ____ ppm Min: ____ Max: ____ ppm Min: ____ Max: ____ ppm Min: ____ Max: ____ ppm Min: ____ Max: ____ ppm Min: ____ Max: ____ ppm Min: ____ | _______ _______ _______ _______ _______ _______ |
ATTENDANT SIGNATURE: ______________ SHIFT: ______________ DATE: ______________
RELIEVED ATTENDANT SIGNATURE: ______________ TIME: ______________ DATE: ______________
CONTINUOUS MONITORING RECORD:
| TIME | H2S (ppm) | O2 % | LEL % | COMMENTS / ACTIONS | ||
|---|---|---|---|---|---|---|
| ______ ______ ______ ______ ______ ______ ______ ______ | _______ _______ _______ _______ _______ _______ _______ _______ | _______ _______ _______ _______ _______ _______ _______ _______ | _______ _______ _______ _______ _______ _______ _______ _______ | ________ ________ ________ ________ ________ ________ ________ ________ |
ANY H2S ALARMS DURING ENTRY? ☐ No ☐ Yes (complete below)
Time of alarm: ______________ H2S level: ______________ ppm Duration: ______________
Action taken: ______________
______________
GAS TESTER / SAFETY OBSERVER SIGNATURE: ______________ DATE: ______________
PERMIT APPLICANT / ENTRY SUPERVISOR (Confirms all preparations complete, team ready):
I confirm that this H2S entry has been properly planned, all hazards assessed, atmospheric testing
is within limits, and all required controls are in place for safe entry.
Signature: ______________ Date: ______________ Time: ______________
ATTENDANT (Confirms understanding of duties and emergency procedures):
I understand my duties as Attendant, including H2S alarm response and emergency procedures.
I will not enter the H2S area to attempt rescue without SCBA.
Signature: ______________ Date: ______________ Time: ______________
ENTRANTS (Confirms understanding of H2S hazards, monitoring, and emergency procedures):
I have been briefed on H2S hazards, understand the monitoring and alarm systems, and consent to enter.
Signature: ______________ Date: ______________ Time: ______________
Signature: ______________ Date: ______________ Time: ______________
Signature: ______________ Date: ______________ Time: ______________
GAS TESTER (Confirms atmospheric testing complete and within limits):
I confirm that atmospheric testing has been completed, H2S levels are <10 ppm, and continuous
monitoring is in place.
Signature: ______________ Date: ______________ Time: ______________
RESCUE TEAM LEADER (Confirms rescue capability and equipment ready):
I confirm that rescue team is available, equipped with SCBA, and ready to respond.
Signature: ______________ Date: ______________ Time: ______________
OPERATIONS / AREA AUTHORITY (Confirms area release for entry):
Signature: ______________ Date: ______________ Time: ______________
SAFETY REPRESENTATIVE (If required):
Signature: ______________ Date: ______________ Time: ______________
FINAL APPROVAL - PERMIT ISSUED BY (HSE / Site Manager):
Signature: ______________ Date: ______________ Time: ______________
PERMIT VALID FOR ENTRY BETWEEN: Start: ______________ Date: ______________ End: ______________ Date: ___________
ENTRY COMPLETED / SUSPENDED / TERMINATED:
Date: ______________ Time: ______________
☐ Entry completed as planned
☐ Entry suspended (reason): ______________
☐ Entry terminated due to H2S alarm / emergency
ENTRANTS ACCOUNTED FOR:
Total entrants at start: _____ Total entrants accounted for at end: _____
Are all entrants out of H2S area? ☐ Yes ☐ No (If No, explain: ______________)
FINAL ATMOSPHERIC TEST:
Time: ______________ H2S: ________ ppm O2: ________ % LEL: ________ %
EQUIPMENT DECONTAMINATION / SHUTDOWN:
☐ SCBA / SAR equipment turned off and secured
☐ Respirators cleaned and stored
☐ Monitors turned off and charged
☐ H2S area secured / isolated
☐ Warning signs removed (if appropriate)
☐ Tools and equipment removed
ATTENDANT DECLARATION:
I confirm that all entrants have exited the H2S area, the area has been secured, and no H2S
alarms are active.
Signature: ______________ Date: ______________ Time: ______________
ENTRY SUPERVISOR DECLARATION:
I confirm that the H2S entry has been completed/suspended and all personnel are accounted for.
Signature: ______________ Date: ______________ Time: ______________
OPERATIONS / AREA AUTHORITY (Area handover acceptance):
Signature: ______________ Date: ______________ Time: ______________
Any incidents, near misses, or unsafe conditions during this H2S entry:
☐ No incidents/near misses
☐ H2S exposure incident (complete below)
☐ Near miss (H2S alarm, equipment failure) (complete below)
☐ Unsafe condition observed (complete below)
DESCRIPTION: ______________
______________
______________
H2S LEVEL IF APPLICABLE: ______________ ppm Duration of exposure: ______________
MEDICAL ATTENTION REQUIRED? ☐ No ☐ Yes (Name: ______________ Treatment: ______________)
CORRECTIVE ACTIONS TAKEN: ______________
______________
REPORTED BY: ______________ Date: ______________ Time: ______________
REPORT NUMBER (if applicable): ______________
H2S KILLS - THIS PERMIT IS VALID ONLY FOR THE DATE AND TIME SPECIFIED
ALL CONDITIONS MUST BE RE-VERIFIED IF H2S LEVELS EXCEED 10 ppm