Free Ventilation Method Statement template for mining you can edit online and download as PDF. Covers operation information, primary ventilation system specifications, ventilation network and airflow distribution.
PROCEDURE ID: VM-__________ DATE: ______________ TIME: ______________
MINE SITE: ______________ LOCATION: ______________ VENT ZONE: ______________
VENTILATION OFFICER: ______________ MINE FOREMAN: ______________
| COMPONENT | SPECIFICATION | CAPACITY | LOCATION | STATUS | LAST TEST DATE | NEXT TEST DATE |
|---|---|---|---|---|---|---|
| Main Fan #1 | Type: Axial/ Centrifugal Dia: ___m | Airflow: ___m³/s SP: ___kPa | Surface/ Underground | ☐ Operating ☐ Standby ☐ Maintenance | ||
| Main Fan #2 | Type: Axial/ Centrifugal Dia: ___m | Airflow: ___m³/s SP: ___kPa | Surface/ Underground | ☐ Operating ☐ Standby ☐ Maintenance | ||
| Booster Fans | Quantity: ___ Type: ___ Power: ___kW | Total: ___m³/s | Locations: ___ | ☐ Operating ☐ Standby ☐ Maintenance | ||
| Auxiliary Fans | Quantity: ___ Type: ___ Power: ___kW | Total: ___m³/s | Working faces: ___ | ☐ Operating ☐ Standby ☐ Maintenance |
| AIRWAY | DIMENSIONS (WxH) m | LENGTH (m) | AIRFLOW (m³/s) | VELOCITY (m/s) | REGULATOR SETTING | PRESSURE DROP (Pa) |
|---|---|---|---|---|---|---|
| Intake Main Intake Branch Working Face 1 Working Face 2 Return Branch Return Main | ___ x ___ ___ x ___ ___ x ___ ___ x ___ ___ x ___ ___ x ___ | _______ _______ _______ _______ _______ _______ | _______ _______ _______ _______ _______ _______ | _______ _______ _______ _______ _______ _______ | N/A N/A ___% open ___% open N/A N/A | _______ _______ _______ _______ _______ _______ |
| LOCATION | TIME | O2 (%) (>19.5%) | CH4 (%) (<1.0%) | CO (ppm) (<50 ppm) | CO2 (%) (<0.5%) | NO2 (ppm) (<5 ppm) |
|---|---|---|---|---|---|---|
| Intake Face 1 Face 2 Return 1 Return 2 Shop Area Refuge Chamber | ||||||
| H2S (ppm) (<10 ppm) | SO2 (ppm) (<5 ppm) | DUST (mg/m³) (<1.5 mg/m³) | TEMP (°C) | HUMIDITY (%) | AIRFLOW (m/s) | MONITORED BY |
| STRUCTURE TYPE | LOCATION | TYPE | SIZE | PRESSURE RATING (Pa) | AIRFLOW (m³/s) | LAST INSPECTION |
|---|---|---|---|---|---|---|
| Regulator Air doors Stopping Overcast Underpass Drop raise | Adjustable/ Fixed Single/Double /Automatic Block/Brattice Concrete/Steel Concrete/Steel Raise/borehole | ___ x ___ ___ x ___ ___ x ___ ___ x ___ ___ x ___ Dia: ___m | _______ _______ _______ _______ _______ _______ | _______ _______ _______ _______ _______ _______ | _______ _______ _______ _______ _______ _______ |
I CERTIFY THAT A COMPLETE VENTILATION SURVEY HAS BEEN CONDUCTED AND ALL READINGS ARE WITHIN MSHA REQUIREMENTS.
SURVEY DATE: ______________ SURVEY TIME: ______________
WEATHER CONDITIONS: ______________ BAROMETRIC PRESSURE: __________ kPa
TOTAL INTAKE AIRFLOW: __________ m³/s TOTAL RETURN AIRFLOW: __________ m³/s SHORTFALL: __________ m³/s
MINIMUM FACE VELOCITY: __________ m/s MAXIMUM FACE VELOCITY: __________ m/s
DEFICIENCIES FOUND: ______________
CORRECTIVE ACTIONS: ______________
VENTILATION OFFICER: ______________ SIGNATURE: ______________
MINE FOREMAN: ______________ SIGNATURE: ______________