Free Ground Support Method Statement template for mining you can edit online and download as PDF. Covers operation information, ground condition assessment and classification, support installation specifications and monitoring.
PROCEDURE ID: GS-__________ DATE: ______________ TIME: ______________
MINE SITE: ______________ LOCATION: ______________ SECTION: ______________
GROUND CONTROL SUPERVISOR: _________ ROCK MECHANIC: ______________
| PARAMETER | MEASUREMENT | RMR RATING | Q-RATING | SUPPORT CATEGORY | SUPPORT TYPE | SUPPORT INTERVAL |
|---|---|---|---|---|---|---|
| Rock Quality Designation (RQD) | UCS: ___ MPa | ___/100 | ___/100 | Category A (RMR 81-100) | Rock bolts only | 0.5-1.0m |
| Joint Characteristics | Spacing: ___mm Condition: ___/30 | ___/100 | ___/100 | Category B (RMR 61-80) | Rock bolts + mesh | 1.0-1.5m |
| Groundwater Conditions | Inflow: ___L/min Pressure: ___MPa | ___/15 | ___/100 | Category C (RMR 41-60) | Rock bolts + mesh + shotcrete | 1.0-1.5m |
| Joint Orientation | Dip: ___° Direction: ___° | ___/20 | ___/100 | Category D (RMR 21-40) | Steel sets + lagging | 0.5-1.0m |
| Stress Conditions | Magnitude: ___MPa Orientation: ___° | ___/0-25 | ___/100 | Category E (RMR <20) | Forepoling + full steel sets | <0.5m |
| SUPPORT TYPE | SPECIFICATIONS | INSTALLATION PATTERN | TORQUE/TENSION REQUIREMENT | TEST FREQUENCY | MONITORING METHOD | VERIFICATION STATUS |
|---|---|---|---|---|---|---|
| Mechanical Rock Bolts | Dia: ___mm Length: ___m Grade: ___ | Spacing: ___m Row: ___m Pattern: staggered | Tension: ___kN Torque: ___Nm | Pull test: every ___m Min 5% of bolts | Load cells: every ___m Convergence points: every ___m | ☐ Installed ☐ Tested ☐ Verified |
| Resin Grouted Bolts | Dia: ___mm Length: ___m Resin type: ___ cartridges | Spacing: ___m Row: ___m Pattern: square | Bond length: ___mm Cure time: ___min | Pull test: every ___m Min 10% of bolts | Extensometers: every ___m Shear strips: every ___m | ☐ Installed ☐ Tested ☐ Verified |
| Cable Bolts | Strands: ___ Length: ___m Capacity: ___kN | Spacing: ___m Row: ___m Pattern: systematic | Grout pressure ___MPa W/C ratio: ___ | Pull test: every ___m Min 5% of bolts | Tell-tales: every ___m Load cells: every ___m | ☐ Installed ☐ Tested ☐ Verified |
| Shotcrete | Thickness: ___mm Mix design: ___MPa Fiber type: ___kg/m³ | Coverage: full face | Application: wet/dry Rebound <___% | Core samples: every ___m² Compressive strength test every ___m² | Adhesion tests: every ___m² Thickness probes: every ___m | ☐ Applied ☐ Tested ☐ Verified |
| Steel Sets | Section: ___ Weight: ___kg/m Capacity: ___kN | Spacing: ___m Footing: ___MPa bearing | Blocking: full contact Lagging: ___mm thick | Load tests: every ___sets Instrumentation on ___sets | Convergence monitoring: daily readings | ☐ Installed ☐ Tested ☐ Verified |
| DATE/TIME | STATION | CONVERGENCE READING (mm) | EXTENSOMETER READING (mm) | LOAD CELL READING (kN) | COMMENTS |
|---|---|---|---|---|---|
| ALARM THRESHOLDS: | Warning Level: ___mm | Action Level: ___mm | Critical Level: ___mm | Rate of Change: ___mm/day |
I CERTIFY THAT THE GROUND SUPPORT INSTALLED IN THIS SECTION COMPLIES WITH THE APPROVED DESIGN SPECIFICATIONS
AND MEETS ALL MSHA SAFETY REQUIREMENTS.
SECTION/FACE: ______________ DATE: ______________
CHAINAGE FROM: __________ TO: __________ SUPPORT CATEGORY: __________
INSTALLATION SUPERVISOR: ______________ SIGNATURE: ______________
QUALITY CONTROL INSPECTOR: ______________ SIGNATURE: ______________
MINE MANAGER: ______________ SIGNATURE: ______________