Free Steel Erection Risk Assessment template for construction you can edit online and download as PDF. Covers steel erection project information, steel erection hazard identification and risk assessment, critical lift plan - osha
ASSESSMENT ID: STL-__________ DATE: ______________ TIME: ______________
PROJECT: ______________ LOCATION: ______________ CONTRACTOR: ______________
STRUCTURE TYPE:
☐ Building Frame ☐ Bridge ☐ Industrial ☐ Tower ☐ Roof Truss ☐ Other: ______________
STEEL SPECIFICATIONS:
Total Tonnage: ______ tons Max Piece Weight: ______ tons Max Lift Height: ______ m (ft)
Connection Types: ☐ Bolted ☐ Welded ☐ Combination
STEEL ERECTOR: ______________ ERECTION SUPERVISOR: ______________
STRUCTURAL ENGINEER: ______________ PE #: ______________
ERECTION START DATE: ______________ ESTIMATED COMPLETION: ______________
ERECTION PLAN:
☐ Erection plan prepared by qualified person: ______________ Date: ___________
☐ Plan includes sequence of erection
☐ Plan includes temporary bracing requirements
☐ Plan includes critical lift identification
☐ Plan includes fall protection procedures
☐ Plan reviewed with all workers pre-erection
DRAWINGS AND DOCUMENTS:
☐ Structural drawings available and current Drawing #: ______________
☐ Shop drawings available Drawing #: ______________
☐ Connection details available Drawing #: ______________
☐ Anchor bolt setting plan available Drawing #: ______________
☐ Field weld procedures (WPS) available #: ______________
SITE CONDITIONS:
☐ Site access for cranes verified
☐ Ground conditions adequate for crane setup
☐ Overhead power lines identified and protected
☐ Underground utilities located and marked
☐ Adjacent structures protected
☐ Public protection measures in place
ENGINEER'S CERTIFICATION:
"I certify that the steel structure and erection plan meet all applicable codes and standards. The structure
is designed to withstand construction loads with the specified temporary bracing."
Name: ______________ PE #: ______________ Date: ___________ Signature: ___________
CRANE INFORMATION:
Crane Type: ______________ Manufacturer: ______________ Model: ______________
Capacity: ______ tons Configuration: ______________ Crane ID: ______________
Operator: ______________ Certification #: ______________ Expiry: ___________
Last Inspection: ___________ Next Inspection: ___________ Annual: ☐ Monthly: ☐ Daily: ☐
| DAILY CRANE INSPECTION CHECKLIST: Item ________ Wire rope/hoist line Hook and latch Boom and jib Outriggers/pads Tires/tracks Hydraulics/leaks Controls Safety devices Load indicator Anti-two block Swing brake Lights/alarms | Satisfactory _____________ ☐ Yes ☐ Yes ☐ Yes ☐ Yes ☐ Yes ☐ Yes ☐ Yes ☐ Yes ☐ Yes ☐ Yes ☐ Yes ☐ Yes | Defect Found _____________ ☐ ☐ ☐ ☐ ☐ N/A ☐ ☐ ☐ ☐ ☐ N/A ☐ ☐ N/A | Corrective Action ________ ________ ________ ________ ________ ________ ________ ________ ________ ________ ________ ________ ________ |
|---|
| RIGGING EQUIPMENT: Equipment Type ________ Slings (wire) Slings (synthetic) Shackles Turnbuckles Spreader bars Lifting lugs Chokers | Size/Capacity ________ ________ _____________ ________ ________ ________ ________ ________ | Condition __________ Good ☐ Bad☐ Good ☐ Bad☐ Good ☐ Bad☐ Good ☐ Bad☐ Good ☐ Bad☐ Good ☐ Bad☐ Good ☐ Bad☐ | Last Inspected ________ ________ ________ ________ ________ ________ ________ ________ | Next Inspected ________ ________ ________ ________ ________ ________ ________ ________ | Tag Color ___________ ___________ ___________ ___________ ___________ ___________ ___________ ___________ |
|---|
Rigger-in-charge: ______________ Certified? Yes ☐ No ☐ Certification #: ______________
| HAZARD | CAUSE | POTENTIAL CONSEQUENCE | EXISTING CONTROLS | LIKELIHOOD (1-5) | SEVERITY (1-5) | RISK RATING (L x S) |
|---|---|---|---|---|---|---|
| Structural Instability / Collapse | -Inadequate temporary bracing -Missing connections -Unsecured columns -Wind loading during erection -Improper erection sequence | -Cascade collapse -Multiple fatalities -Crush injuries -Equipment damage -Schedule delays | -Erection sequence plan -Temporary bracing design -Guying -Anchor bolt verification -Progressive stability checks | 3 (Occasional) | 5 (Catastrophic) | 15 (EXTREME) |
| Falls from Height | -Unprotected edges -Missing fall arrest system -Improper tie-off -Connector rods/beams without protection -Slip on steel surfaces | -Fatalities -Paralysis -Broken bones -Head injury -Permanent disability | -Guardrails (permanent) -Personal fall arrest system (PFAS) -Safety nets -Controlled decking zones -Connector safety (6' rule) | 5 (Frequent) | 5 (Catastrophic) | 25 (EXTREME) |
| Falling Objects | -Unsecured tools -Loose materials -Spanner bags/bolts on beams -Wind blowing materials -Improper storage -Crane loads | -Struck-by injuries -Head injury -Fatality -Equipment damage -Public injury | -Tool tethers -Toeboards -Debris nets -Exclusion zones -Barricades -Material storage limits -Canopies -Hard hats (all workers) | 5 (Frequent) | 4 (Critical) | 20 (EXTREME) |
| Crane Related Hazards | -Overloading -Improper rigging -Swinging loads -Two-blocking -Power line contact -Outrigger failure -Poor communi- cation | -Crane tip -Load drop -Boom collapse -Struck by load -Electro- cution -Crush injuries | -Lift plan for all critical lifts -Rigging inspection -Load indicators -Tag lines -Power line clearance (20' rule) -Qualified operators | 3 (Occasional) | 5 (Catastrophic) | 15 (EXTREME) |
| Bolting Operations | -Improper bolt installation -Incorrect bolt tension -Tool kickback -Ergonomics (awkward positions) -Falling tools/bolts | -Connection failure -Structural instability -Injury from tool kickback -Musculo- skeletal injuries -Struck by falling objects | -Torque wrench calibration -Turn-of-nut method -Direct tension indicators -Work positioning -Tool tethers | 4 (Probable) | 3 (Major) | 12 (HIGH) |
| Welding Operations | -Fire/ explosion -Arc flash -Fumes/gas exposure -Electrical shock -Compressed gas cylinders -Welding in rain/wet conditions | -Burns -Eye damage (arc eye) -Respiratory illness -Electro- cution -Explosion | -Hot work permit -Fire watch required -Welding screens -PPE (hood, gloves, leathers) -Ventilation -Cylinder storage | 3 (Occasional) | 4 (Critical) | 12 (HIGH) |
| Decking Operations | -Open openings -Unsecured deck sheets -Wind lifting sheets -Lack of fall protection -Inadequate decking sequence | -Fall through -Falls -Struck by materials -Crush injuries -Cut hazards (sharp edges) | -Controlled decking zones -Cover openings -Securing deck sheets immediately -Fall protection at leading edge | 4 (Probable) | 5 (Catastrophic) | 20 (EXTREME) |
| Adverse Weather | -High wind (≥20 mph) -Lightning -Rain/ice/snow -Extreme heat -Poor visibility | -Loss of control of loads -Crane instability -Electro- cution -Slips/falls -Heat stress -Hypothermia | -Wind monitoring -Work suspension criteria (wind ≥20 mph stop lifts, ≥30 mph stop all) -Lightning safety (30/30 rule) | 3 (Occasional) | 4 (Critical) | 12 (HIGH) |
LIFT ID: ______________ DATE: ______________ TIME: ______________
DESCRIPTION: ______________
LOAD DETAILS:
Piece: ______________ Weight: ______ tons Dimensions: ______ x ______ x ______
Center of gravity location: ______________
Lift radius: ______ ft Lift height: ______ ft Boom angle: ______ degrees
Crane capacity at this radius/angle: ______ tons % of capacity: ______%
RIGGING DETAILS:
Sling type/size: ______________ Sling capacity: ______ tons # of slings: ______
Sling angle: ______ degrees Reduction factor: ______ Effective capacity: ______ tons
Shackle size/capacity: ______________ Lifting lug capacity: ______ tons
Spreader beam required? Yes ☐ No ☐ Capacity: ______ tons
PERSONNEL:
Lift Director: ______________ Crane Operator: ______________
Signal Person: ______________ Rigger: ______________
Safety Observer: ______________
SITE CONDITIONS:
Ground conditions: ______________ Outrigger pads: ______________
Overhead obstructions: ______________ Power line clearance: ______ ft
Weather conditions: Wind speed: ______ mph Visibility: Good ☐ Fair ☐ Poor ☐
COMMUNICATION:
Primary method: ☐ Radio (channel: ___) ☐ Hand signals ☐ Verbal ☐ Other: ______________
Backup method: ______________
Hand signal card posted? Yes ☐ No ☐
LIFT APPROVAL:
Lift Director: ______________ Date: ___________ Time: ___________
Crane Operator: ______________ Date: ___________ Time: ___________
FALL PROTECTION REQUIREMENTS:
CONNECTORS (workers connecting steel):
☐ Fall protection required at heights > 15 feet (2 stories)
☐ Connectors must be protected from falls > 30 feet
☐ Connector safety: 100% tie-off when possible
☐ Connector training completed: Date: ___________
ALL OTHER WORKERS:
☐ Fall protection required at heights > 15 feet
☐ Guardrail systems ☐ Personal fall arrest systems ☐ Safety nets
☐ Positioning device systems
CONTROLLED DECKING ZONES (CDZ):
☐ CDZ established for initial decking operations
☐ CDZ boundaries clearly marked
☐ Only trained workers allowed in CDZ
☐ CDZ not to exceed 90 feet in width
☐ CDZ not to exceed 3 floors or 50 feet in height
☐ CDZ safety monitoring system in place
PERSONAL FALL ARREST SYSTEMS (PFAS):
Harness type: ______________ Manufacturer: ______________ Last inspected: ___________
Lanyard type: ☐ Shock-absorbing ☐ Self-retracting Length: ______ ft
Anchor points: ______________ Capacity: 5,000 lbs minimum
Clearance calculation: Free fall ≤ 6 ft, Total fall distance: ______ ft
Rescue plan for suspended workers: ______________
SAFETY NETS:
☐ Nets installed where fall hazards exist
☐ Drop test completed: Date: ___________ Results: Pass ☐ Fail ☐
☐ Nets extend 8-13 feet beyond edge
☐ No debris in nets
☐ Nets inspected weekly: Last inspection: ___________
INSPECTOR: ______________ DATE: ______________ TIME: ______________
WEATHER: ______________ WIND: ______ mph TEMP: ______°F/°C
| INSPECTION ITEM | SATISFACTORY | DEFECT FOUND | CORRECTIVE ACTION |
|---|---|---|---|
| PRE-ERECTION: 1. Erection plan reviewed with crew 2. Crane pre-use inspection completed 3. Rigging equipment inspected 4. Anchor bolts/leveling plates checked 5. Site ground conditions adequate | ☐ Yes ☐ Yes ☐ Yes ☐ Yes ☐ Yes | ☐ ☐ ☐ ☐ ☐ | ________ ________ ________ ________ ________ |
| STRUCTURAL STABILITY: 6. Erected steel plumb and level 7. Temporary bracing installed per plan 8. Connections properly made (bolts/welds) 9. No unsecured members 10. Structure stable before releasing crane | ☐ Yes ☐ Yes ☐ Yes ☐ Yes ☐ Yes | ☐ ☐ ☐ ☐ ☐ | ________ ________ ________ ________ ________ |
| FALL PROTECTION: 11. Connectors tied-off where required 12. Other workers using fall protection 13. Anchor points adequate and identified 14. Leading edge protection in place 15. Safety nets installed (if used) | ☐ Yes ☐ Yes ☐ Yes ☐ Yes ☐ Yes | ☐ ☐ N/A ☐ ☐ ☐ N/A | ________ ________ ________ ________ ________ |
| FALLING OBJECT PROTECTION: 16. Toeboards installed where required 17. Tool tethers in use 18. Debris nets/ canopies in place 19. Materials stored securely 20. Exclusion zones below work | ☐ Yes ☐ Yes ☐ Yes ☐ Yes ☐ Yes | ☐ ☐ ☐ N/A ☐ ☐ | ________ ________ ________ ________ ________ |
| CRANE OPERATIONS: 21. Crane setup/outriggers adequate 22. Power line clearance maintained 23. Tag lines used on loads 24. Load chart and capacity limits observed 25. Communications effective | ☐ Yes ☐ Yes ☐ Yes ☐ Yes ☐ Yes | ☐ ☐ N/A ☐ ☐ ☐ | ________ ________ ________ ________ ________ |
| HOUSEKEEPING: 26. Work areas clear of debris 27. Bolts/tools stored properly 28. Walkways and access clear | ☐ Yes ☐ Yes ☐ Yes | ☐ ☐ ☐ | ________ ________ ________ |
OVERALL ASSESSMENT:
Is steel erection safe to continue? Yes ☐ No ☐ (If No, stop work immediately)
CORRECTIVE ACTIONS TAKEN:
______________
______________
FOREMAN SIGNATURE: ______________ DATE: ___________
| COLUMN/GRID ________ ________ ________ ________ ________ ________ | CONNECTION TYPE ________ ________ ________ ________ ________ ________ | BOLTS INSTALLED ________ ________ ________ ________ ________ ________ | TORQUE VALUE ____________ ____________ ____________ ____________ ____________ ____________ | INSPECTED __________ __________ __________ __________ __________ __________ | ACCEPTED _________ _________ _________ _________ _________ _________ | DATE ___________ ___________ ___________ ___________ ___________ ___________ |
|---|
| WELD INSPECTION LOG: Weld ID _______ _______ | Type _____ _____ | Size _____ _____ | Visual Insp ___________ ___________ | NDT Method __________ __________ | NDT Results ___________ ___________ | Accepted ________ ________ | Inspector __________ __________ | Date ___________ ___________ |
|---|
REQUIRED PPE:
☐ Hard hat (with chin strap if working at height)
☐ Safety glasses with side shields
�| High-visibility vest
☐ Steel-toed boots (with non-slip soles)
�| Leather gloves (for handling steel)
☐ Hearing protection (near cranes/equipment)
☐ Full body harness with lanyard (fall protection)
☐ Welding PPE (hood, gloves, leathers) - as required
☐ Face shield (for grinding/cutting)
☐ Sun protection
TOOL TETHERS:
Required for all tools at height? Yes ☐ No ☐
Tether type: ☐ Lanyard ☐ Retractable ☐ Bungee
Approved for tool weight? Yes ☐ No ☐
POTENTIAL EMERGENCIES:
☐ Structural collapse ☐ Fall from height ☐ Crane accident ☐ Fire/explosion
☐ Medical emergency ☐ Electrical contact ☐ Welding fire ☐ Severe weather
☐ Suspended worker rescue
EMERGENCY CONTACTS:
EMERGENCY: 911
Site Safety Officer: ______________ Phone: ______________
Erection Supervisor: ______________ Phone: ______________
Project Manager: ______________ Phone: ______________
Nearest Hospital: ______________ Phone: ______________
RESCUE PROCEDURES FOR SUSPENDED WORKERS:
1. Assess situation - DO NOT become victim
2. Call 911 - advise of suspended worker
3. Communicate with suspended worker
4. Initiate pre-planned rescue:
☐ Self-rescue (descender device)
☐ Aerial lift rescue
☐ Crane rescue with personnel basket
☐ Wait for emergency services
5. Provide first aid after rescue
6. Complete incident report
RESCUE EQUIPMENT LOCATION:
Rescue descender: ______________
Personnel basket: ______________
Ladder: ______________
First aid kit: ______________
STRUCTURAL COLLAPSE PROCEDURES:
1. Clear area immediately - evacuate to assembly point
2. Account for all personnel
3. Call 911 - advise of collapse and potential trapped workers
4. DO NOT re-enter structure - wait for emergency services
5. Secure perimeter - prevent unauthorized access
EVACUATION ROUTES:
Primary: ______________
Secondary: ______________
Assembly Point: ______________
TRAINING REQUIREMENTS - OSHA 29 CFR 1926.761
| TOPIC ________ Steel Erection Safety Orientation Fall Protection for Steel Erectors Connector Safety Crane and Rigging Safety Critical Lift Procedures Bolting/Welding Procedures Site-Specific Erection Plan Emergency Procedures | TRAINER ________ ________ ________ ________ ________ ________ ________ ________ ________ | DATE ___________ ___________ ___________ ___________ ___________ ___________ ___________ ___________ ___________ | ATTENDEES ________ ________ ________ ________ ________ ________ ________ ________ ________ |
|---|
COMPETENT PERSON DESIGNATION:
Name: ______________ Title: ______________ Experience: ______ years
Responsibilities:
☐ Daily inspections of steel erection operations
☐ Verify temporary bracing installation
☐ Ensure fall protection compliance
☐ Identify and correct hazards
☐ Stop work when unsafe conditions exist
CRANE OPERATOR CERTIFICATION:
Name: ______________ Cert #: ______________ Expiry: ___________
Name: ______________ Cert #: ______________ Expiry: ___________
RIGGER CERTIFICATION:
Name: ______________ Cert #: ______________ Level: Basic ☐ Advanced ☐
SIGNAL PERSON CERTIFICATION:
Name: ______________ Qualified by: ______________ Date: ___________
| PERMIT TYPE ________ Crane Use Permit Critical Lift Permit Hot Work Permit (welding) Steel Erection Permit Overheight Transport | ISSUING AUTHORITY ________ ________ ________ ________ ________ ________ | PERMIT # _____________ _____________ _____________ _____________ _____________ _____________ | ISSUE DATE ___________ ___________ ___________ ___________ ___________ ___________ | EXPIRY DATE ___________ ___________ ___________ ___________ ___________ ___________ |
|---|
NOTIFICATIONS COMPLETED:
☐ OSHA (if applicable) Date: ___________ Confirmation #: ______________
�| Local authorities (road closures) Date: ___________ Contact: ______________
☐ Adjacent property owners Date: ___________ Method: ______________
OVERALL RISK ASSESSMENT:
Based on the identified hazards and existing controls, the overall risk level for this steel erection is:
☐ LOW - Routine erection with minimal hazards, controls adequate
☐ MEDIUM - Moderate hazards, requires ongoing monitoring
☐ HIGH - Significant hazards, requires active controls and frequent inspection
☐ EXTREME - Severe hazards, requires engineering controls and specialized oversight
CRITICAL CONTROLS REQUIRED:
1. ______________
2. ______________
3. ______________
4. ______________
5. ______________
WORK STOPPING AUTHORITY:
All personnel have the authority and responsibility to stop work if conditions become unsafe.
Stop work protocol: Notify supervisor immediately, secure area, correct condition before resuming.
ERECTION SUPERVISOR:
"I have reviewed this risk assessment and confirm that all identified hazards have been addressed with
appropriate controls. All required permits and notifications are complete."
Name: ______________ Signature: ______________ Date: ___________
PROJECT MANAGER:
"I approve the steel erection plan and risk assessment. Resources are allocated for all required controls."
Name: ______________ Signature: ______________ Date: ___________
SAFETY OFFICER:
"I have verified that all safety requirements are met and that steel erection can proceed safely."
Name: ______________ Signature: ______________ Date: ___________
CRANE OPERATOR:
"I have reviewed the lift plan and confirm that I understand my role in safe steel erection."
Name: ______________ Signature: ______________ Date: ___________
NEXT REVIEW DATE: ______________